Refrigerant selection – the balancing act

Refrigerant selection has become an extremely complex task with F-gas legislation requiring a reduction in the use of HFC refrigerants and a move towards the use of refrigerants with lower global warming potential (GWP).

There is no off-the shelf solution when it comes to refrigerants, particularly for low temperature applications. It’s a balancing act between GWP, toxicity and flammability.

A2L refrigerants

They meet the F-gas legislation criteria of low GWP, however, are classed as mildly flammable, which obviously poses safety risks when it comes to their transportation and handling.

Therefore, systems need to be designed in-line with refrigerant development, preferably without the need for special transport and storage arrangements or imposing severe commercial pressures.

Consider suitable segregation, component choice and eliminating ignition sources where appropriate. Installing a suitable leak detection system to shut down the system and a forced ventilation system which activates upon detection of a leak will protect workers.

With more flammable refrigerants coming to the fore, the importance of safer logistics, better fire-proofing, and keeping systems secure to prevent leakage is paramount. Refrigerants should be contained, recovered, and disposed of, ethically.

Natural refrigerants

These include carbon dioxide (CO2) and ammonia (NH3) which have low GWP. They won’t suit every application, for example, ammonia provides high efficiency and performance with low environmental impact. However, it has high toxicity, can be flammable in certain circumstances, and is highly corrosive to copper which is an issue for many semi-hermetic compressors – often relying on having electric motors with copper windings.

Drop-in refrigerants

These are intended to replace your original refrigerant when phased out and often have GWP values over 150 and are never 100% like-for-like, therefore compromising performance or energy consumption. Systems often need altering before a drop-in refrigerant can be used too, including changes to the expansion valve, additional liquid suction heat exchangers, or changing the oil to a different type.

There is no straightforward answer when it comes to refrigerant choice, and with the market saturated with conflicting information, users need to be aware of the compromises associated with hastily opting for low GWP and drop-in refrigerants.

To make the process simpler, your equipment manufacturer should be able to advise you on the best refrigerant for your equipment and application.

For more information about refrigerant selection and process temperature control solutions, call 0800 774 7426 or email info@icscoolenergy.com.

 

Related Articles

reduce process cooling costs

February 15, 2024

5 Tips To Reduce Your Process Cooling Energy Costs

Refrigeration accounts for a high proportion of overall site energy costs, most notably cooling for food, drink, chemical, and pharmaceutical processes where up to 90%...

Read More

February 7, 2024

What Is A Chiller? Core Uses, Types & How They Work

At its core, a chiller is a refrigeration system designed to remove heat through a vapor-compression, absorption, or adsorption refrigeration cycle. The primary objective is...

Read More
Preparing chillers for summer

May 31, 2023

Preparing Your Chiller For Summer

Summer is an unreliable season and hot weather tends to surprise us – usually during the working week when we have little time to enjoy...

Read More